Maple-systems MAPware-100 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Computerzubehör Maple-systems MAPware-100 herunter. Maple Systems MAPware-100 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Table Of Contents
GETTING STARTED .....................1
What You Will Need ..................1
Step 1: Install the MAPware 100
Configuration Software ................1
Step 2: Create Your First MAPware 100
Project.............................4
Step 3: Connect the Operator Interface
Terminal to the PC ....................6
Step 4: Send Your Project to the Operator
Interface Terminal ....................7
Step 5: Connect the Operator Interface
Terminal to the PLC ...................7
Conclusion .........................8
OPERATION...........................9
Menu Bar ..........................10
Tool Bar............................10
New Project ......................11
Open Existing Project ...............11
Print Project ......................12
Save Project......................12
Cut............................13
Copy ...........................13
Paste ...........................13
Align Left, Center, Right .............13
Clear Current Message ............14
Blink ...........................14
Insert Special Character .............14
Register Monitor Editor..............16
Example Group Box .............17
Data Group Box................17
Field Attributes Group Box ........18
Limits Box ....................19
ASCII Table Button..............20
Go To Message ...................21
Configuration Editor ...............21
OIT - PLC Interface Settings
Group Box ....................22
OIT Options Group Box ..........22
Function Key Editor ................24
Communication Options ............25
Read from OIT ....................26
Send to OIT ......................27
Help ...........................28
OIT/PLC Identification .................28
Basic Screen Characteristics .............28
Message Editor ...................29
Message Scroll Bar.................29
General Options Group Box..........29
OIT Memory Used Group Box............30
Message Utilization ...................30
TROUBLE SHOOTING ...................32
MAPware 100 Does Not Transfer a
Project to the OIT..................32
OIT Screen is Blank and the OIT is
Beeping .......................32
The OIT Does Not Attach to the PLC..32
Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any
form or by any means, electronic or mechanical, for any purpose, without the express written permission of Maple Systems, Inc.
© 1997 Maple Systems, Inc.
Microsoft and MS-DOS are registered trademarks, and Windows is a trademark of Microsoft Corporation.
Seitenansicht 0
1 2 3 4 5 6 ... 33 34

Inhaltsverzeichnis

Seite 1 - Table Of Contents

Table Of ContentsGETTING STARTED ...1What You Will Need ...1Step 1: Install the MAPware 100Configuration Software ...

Seite 2 - GETTING STARTED

OPERATIONSince MAPware 100 has been designed to run under the Microsoft Windows environment, itconforms to the Windows user interface standard. Many o

Seite 3 - 2 GETTING STARTED

Menu BarThe menu bar contains all of the menus that can be used to navigate through the program.Accessing the menus is simple: either point to one wit

Seite 4

•Send to OIT: Sends a project from MAPware 100 to the OIT (pg. 27).•Help: Context-sensitive help (pg. 28).New ProjectThe New Project button is the sho

Seite 5 - 4 GETTING STARTED

Project files may be stored anywhere on your computer system. Use the Drives andDirectories box for selecting the proper path. Projects that have prev

Seite 6

While you are working on a project, all of the data entered is temporarily saved within thePC’s memory. Nothing is saved permanently until the Save or

Seite 7 - 7431-0050A

Clear Current MessageThe Clear Current Message button is the shortcut for the Edit/Clear Message menu item. TheClear Current Message button is used to

Seite 8

Characters can be selected in two ways: By double-clicking on the desired character, or byclicking once on the desired character and then clicking on

Seite 9 - Conclusion

Register Monitor EditorThe Register Monitor Editor button is the shortcut for the Insert/PLC Register Monitor menuitem. Register monitors are objects

Seite 10 - OPERATION

Notes: Double clicking on a current Register Monitor (or pressing the Register Monitor Editorbutton with the monitor highlighted) enables you to edit

Seite 11 - Tool Bar

correspond to a displayable ASCII character, then the OIT will continue to show the lastdisplayable ASCII character that was in the PLC register, or i

Seite 12 - Open Existing Project

The MAPware 100 User’s Guide explains how to install and use the MAPware 100 configuration softwareand how to get your MAP Family Operator Interface T

Seite 13 - Save Project

Special EffectsCommas make the data easier to read by a human by simply inserting a comma in every1,000th place (every 3 digits). For example, instead

Seite 14 - Align Left, Center, Right

operator attempts to enter data outside the bounds, he will be notified with an error screenindicating that the data is not within bounds. Data will n

Seite 15 - Insert Special Character

Go To MessageThe Go To Message button is the shortcut for the Edit/Go To Message menu item. Thisbutton gives the system programmer the ability to rand

Seite 16 - MAP320D Special Character Set

Note: If you are experiencing problems with communicating with the selected PLC, firstverify that the communication parameters are set to the default

Seite 17 - Register Monitor Editor

The Delay box is used to select the time that must elapse since the last keypress on the OIT orthe last message received from the PLC before the scree

Seite 18 - 1010-0089, REV00

If the Current Message Register is enabled, an address must be specified in the Address textbox. Pressing the Default button, resets the address to th

Seite 19 - 18 OPERATION

The Action box is used to dictate the operation of each key. To select a key, use the mouse to clickon a function key in the Status box. The selected

Seite 20

Notice that COM Ports 1 through 4 are supported, although most machines typically haveCOM1 and COM2. The port needs to be set once.Three options are a

Seite 21 - 20 OPERATION

If you select Options, the Communications Options screen appears.Note: If you have Prompt for Save As enabled (default), you will be prompted for a fi

Seite 22 - Configuration Editor

OIT is using the latest revisions, then proceed to download all of the data and screens createdusing the MAPware 100 configuration software. While the

Seite 23 - Default button on the mouse

4. Enter a:\setup (Substitute B for A if your 3.5-inch floppy drive is configured as a Bdrive).5. Choose the OK button.6. The Setup program starts. De

Seite 24

other. To enable chaining, click on the Chain check box and enter the message number toconnect to. When the OIT is functioning, the operator presses t

Seite 25 - Function Key Editor

OIT Memory Used Group BoxOIT Memory Used is an indicator that displays the amount of memory that has beenconsumed. No more configuration data may be s

Seite 26 - Communication Options

If you use the mouse, you can click on any of the displayed messages. In the Characteristicsarea located at the bottom of the screen, the message you

Seite 27 - Read from OIT

TROUBLE SHOOTINGMAPware 100 Does Not Transfer a Project to the OITIf MAPware 100 halts during a download or indicates that the OIT is not connected:1.

Seite 28 - Send to OIT

3. Power is not being supplied to the PLC. Check power supply and cabling to ensure asuccessful power connection.4. The default values in the Configur

Seite 29 - Basic Screen Characteristics

10. Setup will then show you total space required and space available for installation ofMAPware 100. Choose the Continue button. If adjustment is nee

Seite 30 - General Options Group Box

Step 2: Create Your First MAPware 100 Project1. Double click on the MAPware 100 icon in the Windows Program Manager.2. MAPware 100 starts and, after a

Seite 31 - Message Utilization

5. The Configuration Editor dialog box appears (see Figure 3). This dialog box allowsyou to tailor your MAP Family Operator Interface Terminal to your

Seite 32

9. The Save As dialog box appears. Type firstoit.mwr into the File Name text box.10. Choose the OK button. You have now created your first MAPware 100

Seite 33 - TROUBLE SHOOTING

Step 4: Send Your Project to the Operator Interface Terminal1. Apply 24 VDC to the OIT. At this point the OIT will display the following messages:***S

Seite 34 - TROUBLE SHOOTING 33

ConclusionYou have now created your first MAP Family Operator Interface Terminal project. Pleasetake the time to review all the documentation provided